Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-BD0BH0-P-A-DK00000 Advanced Energy CX10S-BD0BH0-P-A-DK00000 -
RFQ
ECAD 7847 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BD0BH0-P-A-DK00000 EAR99 8504.40.9540 1 660W 5 93% 12V 48V 12V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 15 A 6 A 3 A
CX10S-BBCDBH-P-A-DK00000 Advanced Energy CX10S-BBCDBH-P-A-DK00000 -
RFQ
ECAD 7253 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBCDBH-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 12V 12V 24V 48V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 8.3 A 4.17 A 15 A 6 A
CX10S-0DGCDA-P-A-DK00000 Advanced Energy CX10S-0DGCDA-P-A-DK00000 -
RFQ
ECAD 1473 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DGCDA-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 48V 24V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 8.3 A 4.17 A 21 A
CX10S-BCGGCH-P-A-DK00000 Advanced Energy CX10S-BCGGCH-P-A-DK00000 -
RFQ
ECAD 9920 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCGGCH-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 12V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 3 A 3 A 3 A 3 A
CX10S-DBAAB0-P-A-DK00000 Advanced Energy CX10S-DBAAB0-P-A-DK00000 -
RFQ
ECAD 8061 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBAAB0-P-A-DK00000 EAR99 8504.40.9540 1 770W 5 93% 48V 12V 5V 5V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 21 A 21 A 15 A
CX10S-CGGBDH-P-A-DK00000 Advanced Energy CX10S-CGGBDH-P-A-DK00000 -
RFQ
ECAD 2507 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGGBDH-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 24V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 3 A 3 A 15 A
VI-NU4-CM-CC Vicor Corporation VI-NU4-CM-CC -
RFQ
ECAD 4410 0.00000000 Vicor Corporation * Bulk Obsolete VI-NU4 - 1 (Unlimited) REACH Affected EAR99 8504.40.9540 1
CFM40M120 Cincon Electronics Co. LTD CFM40M120 28.8400
RFQ
ECAD 2645 0.00000000 Cincon Electronics Co. LTD CFM40M (40W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 3.00" L x 2.00" W x 0.91" H (76.2mm x 50.8mm x 23.1mm) Chassis Mount Open Frame Universal Input CE, cURus, FCC, TUV 90 ~ 264 VAC - ROHS3 Compliant Not Applicable REACH Unaffected 2034-3701 EAR99 8504.40.9510 1 40W 1 86% 12V - - - - - - 5.656 kV 3.34 A
CX10S-0DACD0-P-A-DK00000 Advanced Energy CX10S-0DACD0-P-A-DK00000 -
RFQ
ECAD 5506 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DACD0-P-A-DK00000 EAR99 8504.40.9540 1 705W 4 93% 48V 5V 24V 48V - - No 60601-1; 60950-1; 62368-1
CX10S-DDDCAB-P-A-DK00000 Advanced Energy CX10S-DDDCAB-P-A-DK00000 -
RFQ
ECAD 3243 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDDCAB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 48V 48V 48V 24V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 4.17 A 8.3 A 21 A 15 A
CX10S-GBCHDC-P-A-DK00000 Advanced Energy CX10S-GBCHDC-P-A-DK00000 -
RFQ
ECAD 7037 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBCHDC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 12V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 8.3 A 6 A 3 A
CX10S-DGHBA0-P-A-DK00000 Advanced Energy CX10S-DGHBA0-P-A-DK00000 -
RFQ
ECAD 3064 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGHBA0-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 48V 24V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 6 A 3 A 15 A
CX10S-CHAHGH-P-A-DK00000 Advanced Energy CX10S-CHAHGH-P-A-DK00000 -
RFQ
ECAD 3999 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHAHGH-P-A-DK00000 EAR99 8504.40.9540 1 725W 10 93% 24V 5V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 21 A 6 A 3 A
CX10S-HBCGG0-P-A-DK00000 Advanced Energy CX10S-HBCGG0-P-A-DK00000 -
RFQ
ECAD 3955 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBCGG0-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 5V 24V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 8.3 A 3 A 3 A
CX10S-DCBDAH-P-A-DK00000 Advanced Energy CX10S-DCBDAH-P-A-DK00000 -
RFQ
ECAD 4533 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCBDAH-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 48V 24V 12V 48V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 4.17 A 21 A 6 A
IMP4-3E0-1L0-1L0-00-A Artesyn Embedded Power IMP4-3E0-1L0-1L0-00-A -
RFQ
ECAD 8679 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-3E0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant Not Applicable EAR99 8504.40.9540 1 1158W 3 85% 5V 12V 12V - - - No 2 kV 150 A 17 A 17 A
CX10S-CGGD0H-P-A-DK00000 Advanced Energy CX10S-CGGD0H-P-A-DK00000 -
RFQ
ECAD 9013 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGGD0H-P-A-DK00000 EAR99 8504.40.9540 1 740W 8 93% 24V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 3 A 3 A 4.17 A
CX10S-GGA0G0-P-A-DK00000 Advanced Energy CX10S-GGA0G0-P-A-DK00000 -
RFQ
ECAD 3850 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGA0G0-P-A-DK00000 EAR99 8504.40.9540 1 465W 7 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 21 A 3 A
WP7-779301-EL Vicor Corporation WP7-779301-EL -
RFQ
ECAD 6705 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WP7-779301-EL OBSOLETE 1
CX10S-BCBDB0-P-A-DK00000 Advanced Energy CX10S-BCBDB0-P-A-DK00000 -
RFQ
ECAD 8826 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCBDB0-P-A-DK00000 EAR99 8504.40.9540 1 740W 5 93% 12V 24V 12V 48V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 15 A 4.17 A 15 A
VI-PU03-CYY Vicor Corporation VI-PU03-CYY -
RFQ
ECAD 7947 0.00000000 Vicor Corporation * Bulk Obsolete VI-PU03 - 1 (Unlimited) REACH Affected EAR99 8504.40.9520 1
CX10S-AGDD0D-P-A-DK00000 Advanced Energy CX10S-AGDD0D-P-A-DK00000 -
RFQ
ECAD 9755 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGDD0D-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 5V 24V 24V 48V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 4.17 A 4.17 A 4.17 A
WX1-7213977-MI Vicor Corporation WX1-7213977-MI -
RFQ
ECAD 9015 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WX1-7213977-MI OBSOLETE 1
CX10S-00DADA-P-A-DK00000 Advanced Energy CX10S-00DADA-P-A-DK00000 -
RFQ
ECAD 4612 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00DADA-P-A-DK00000 EAR99 8504.40.9540 1 610W 4 93% 48V 5V 48V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 4.17 A 21 A
CX10S-BDACDH-P-A-DK00000 Advanced Energy CX10S-BDACDH-P-A-DK00000 -
RFQ
ECAD 1122 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BDACDH-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 12V 48V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 21 A 8.3 A 4.17 A 6 A
VCCM600M-B0CC-DK000 Vox Power Ltd. VCCM600M-B0CC-DK000 460.9660
RFQ
ECAD 2502 0.00000000 Vox Power Ltd. VCCM600M Box Active -40°C ~ 70°C Medical 7.00" L x 4.00" W x 1.57" H (177.8mm x 101.6mm x 40.0mm) Chassis Mount Open Frame Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input VCCM600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-VCCM600M-B0CC-DK000 EAR99 8504.40.9540 1 450W 3 90% 12V 24V 24V - - - No 4 kV 60601-1 15 A 7.5 A 7.5 A
CX10S-DCGGCC-P-A-DK00000 Advanced Energy CX10S-DCGGCC-P-A-DK00000 -
RFQ
ECAD 9922 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCGGCC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 3 A 3 A 3 A 3 A
CX10S-CDC0D0-P-A-DK00000 Advanced Energy CX10S-CDC0D0-P-A-DK00000 -
RFQ
ECAD 7959 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDC0D0-P-A-DK00000 EAR99 8504.40.9540 1 800W 4 93% 24V 48V 24V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 8.3 A 4.17 A
CX10S-AGGGGB-P-A-DK00000 Advanced Energy CX10S-AGGGGB-P-A-DK00000 -
RFQ
ECAD 9540 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGGGGB-P-A-DK00000 EAR99 8504.40.9540 1 765W 10 93% 5V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 3 A 3 A 3 A
NMP1K2-EHHCKK-02 MEAN WELL USA Inc. NMP1K2-EHHCKK-02 821.0300
RFQ
ECAD 9473 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 12V 24V 24V 5V 48V 48V - 4 kV 60601-1; 62368-1 20 A 10 A 10 A 36 A 5 A 5 A